Request a
calculation form

Home / Profiles / Flat profiles / INCO 72.1 Tray

INCO 72.1 Tray

cubierta,fachada
  • Industrial roofing and facade
  • Cover width: 425 mm
  • Profile depth: 72 mm

Roofing

Facade

Geometry

The INCO 72.1 profile is used as a support profile on multi-layer roofs and facades of industrial warehouses, shopping centers, sports facilities and other buildings. This profile offers great resistance for different metal enclosure solutions, offering a cover width of 425 mm and a profile depth of 72 mm. The tray is fixed on frames and this allows the insulation to be accommodated and the external cladding profile to be fixed to the ribs of the tray, while on the inside it provides a flat finished surface.

It is available in both galvanized steel and a variety of painted colors. Furthermore, for interior applications that require improved sound absorption, it can be manufactured in micro-perforated steel with perforations in the central part of the tray.

  • Industrial: hangars, warehouses and production centers
  • Logistics: warehouses and distribution centers
  • Commercial: canopies and shopping centers
  • Public: schools, markets and hospitals
  • Sports: stands, sports courts and pavilions
  • Agricultural: stables, farms and sheds
  • Minimum/maximum manufacturing length: 2 / 14 m
  • Thickness range: 0,60 | 0,70 | 0,75 | 0,80 | 1,00 mm
  • Minimum order: 250 m²
  • Package weight: 1.500 – 2.000 kg
  • Color: White RAL 9003. Others on request
  • Galvanized steel (Z) and Magnelis (ZM)
  • Standard painted steel (15-25 µm)
  • High-performance steel (35-200 µm)
  • Perforated for acoustic solutions

Projects

Start designing yout project

Request calculation report

Complete the form below to receive a detailed report justifying the most suitable enclosure profile. You will receive the information as soon as possible.

Building characteristics
Industrial roof application loads
(1) For sections of the roof profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Application loads for the industrial facade
(1) For sections of the façade profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that are presented in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Deck loads
(1) For sections of the roof profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Structure features
Composite slab characteristics
(1) For the sections of the composite slab with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project. Span length < 5,00 m.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Characteristics of the facade
Roof typology

(1) Indicate the length of the span of the arch, which is the greatest horizontal distance between the supports of the curved roofing.

(2) Plan-view dimension representing the full length of the curved roof measured perpendicular to the arch span.

(3) Specify the obstructed area under the canopy, in square meters, as a proportion of the total area of the front or side (transverse or longitudinal) façade, in order to calculate the obstruction factor. If it is a closed construction or there is no obstruction area, indicate 0 m².

Environment characteristics
Type of environment
Attached documentation
Additional comments
Contact information
Project data

Latest projects