Home / Profiles / Curved profiles / INCO 100.3 Curved

INCO 100.3 Curved

cubierta
  • Self-supporting curved roofing
  • Cover width: 825 mm
  • Profile depth: 100 mm
  • Profile pitch: 275 mm

Roofing

Geometry

The INCO 100.3 Curved profile is used as a curved support profile for simple or multi-layer self-supporting curved roofs of industrial warehouses, shopping centers, sports facilities and other buildings. This profile offers great resistance for different self-supporting curved roof solutions, reaching spans of up to 18 m without intermediate supports, offering a cover width of 825 mm, a profile depth of 100 mm and a profile pitch of 275 mm.

It is available in both galvanized steel and a variety of painted colors. Additionally, for interior applications that require improved acoustic absorption, it can be manufactured from micro-perforated steel.

  • Industrial: hangars, warehouses and production centers
  • Logistics: warehouses and distribution centers
  • Commercial: canopies and shopping centers
  • Public: schools, markets and hospitals
  • Sports: stands, sports courts and pavilions
  • Agricultural: stables, farms and sheds
  • Min/max manufacturing length: 8 / 23 m
  • Thickness range: 0,60 | 0,70 | 0,75 | 0,80 | 1,00 | 1,20 | 1,50mm
  • Minimum order: 250 m²
  • Package weight: 1.500 – 2.000 kg
  • Color: White RAL 9003. Others on request
  • Galvanized steel (Z) and Magnelis (ZM)
  • Standard painted steel (15-25 µm)
  • High-performance steel (35-200 µm)
  • Perforated for acoustic solutions

Projects

Start designing yout project

Request calculation report

Complete the form below to receive a detailed report justifying the most suitable enclosure profile. You will receive the information as soon as possible.

Building characteristics
Industrial roof application loads
(1) For sections of the roof profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Application loads for the industrial facade
(1) For sections of the façade profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that are presented in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Deck loads
(1) For sections of the roof profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Structure features
Composite slab characteristics
(1) For the sections of the composite slab with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project. Span length < 5,00 m.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Characteristics of the facade
Roof typology

(1) Indicate the length of the span of the arch, which is the greatest horizontal distance between the supports of the curved roofing.

(2) Plan-view dimension representing the full length of the curved roof measured perpendicular to the arch span.

(3) Specify the obstructed area under the canopy, in square meters, as a proportion of the total area of the front or side (transverse or longitudinal) façade, in order to calculate the obstruction factor. If it is a closed construction or there is no obstruction area, indicate 0 m².

Environment characteristics
Type of environment
Attached documentation
Additional comments
Contact information
Project data

Latest projects