Request a
calculation form

Home / Projects / INCO 100.3 A Web Perforated R5T8

INCO 100.3 A Web Perforated R5T8

fachada,cubierta
  • Industrial roof, steel deck roof and acoustic industrial façade
  • Cover width: 825 mm
  • Profile depth: 100 mm
  • Profile pitch: 275 mm
  • R5T8 perforation in the webs

Roofing

Geometry

The INCO 100.3 A profile is used as a support profile in multi-layer roofs and façades. It is a support profile with perforations in the webs for acoustic applications. It is used as a support profile in multi-layer roofs and façades, as well as in steel deck roofs for industrial buildings, shopping centres, sports facilities and other types of buildings. It offers high strength for different types of metal cladding systems, with an effective width of 825 mm, a rib height of 100 mm and a rib spacing of 275 mm.

It is available in both galvanized steel sheet and a wide range of pre-painted finishes, adapting to the aesthetic and functional requirements of each project.

This profile can also be manufactured curved with self-supporting capacity, allowing its use as a support profile for single or multi-layer self-supporting curved roofs.

  • Industrial: hangars, warehouses and production centers
  • Logistics: warehouses and distribution centers
  • Commercial: canopies and shopping centers
  • Public: schools, markets and hospitals
  • Sports: stands, sports courts and pavilions
  • Agricultural: stables, farms and sheds
  • Minimum/maximum manufacturing length: 2,2 / 24 m
  • Thickness range: 0.60 | 0.70 | 0.75 | 0.80 | 1.00 | 1.20 | 1.50 mm
  • Minimum order: 250 m²
  • Package weight: 1.500 – 2.000 kg
  • Perforación en las almas R5T8
  • Color: White RAL 9003. Others on request
  • Galvanized steel (Z) and Magnelis (ZM)
  • Standard painted steel (15-25 µm)
  • High-performance steel (35-200 µm)
  • Perforated for acoustic solutions

Projects

Start designing yout project

Request calculation report

Complete the form below to receive a detailed report justifying the most suitable enclosure profile. You will receive the information as soon as possible.

Building characteristics
Industrial roof application loads
(1) For sections of the roof profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Application loads for the industrial facade
(1) For sections of the façade profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that are presented in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Deck loads
(1) For sections of the roof profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Structure features
Composite slab characteristics
(1) For the sections of the composite slab with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project. Span length < 5,00 m.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Characteristics of the facade
Roof typology

(1) Indicate the length of the span of the arch, which is the greatest horizontal distance between the supports of the curved roofing.

(2) Plan-view dimension representing the full length of the curved roof measured perpendicular to the arch span.

(3) Specify the obstructed area under the canopy, in square meters, as a proportion of the total area of the front or side (transverse or longitudinal) façade, in order to calculate the obstruction factor. If it is a closed construction or there is no obstruction area, indicate 0 m².

Environment characteristics
Type of environment
Attached documentation
Additional comments
Contact information
Project data

Latest projects