Renovación de cubierta deck para concesionarios en Cocentaina, perfil INCO 100.3

Rehabilitation of the deck roof of a dealer group in Cocentaina (Valencia) – Spain

Building type: Dealers

Country: España

Province: Valencia/València

Year of construction: 2024

Amount: 4.000 m2

Finish: Granite 25 pre-painted steel

Related systems:

Related products:

The rehabilitation of the roofs of several dealerships has been carried out with the INCO 100.3 Deck profile, arranged at a separation of 3.00 meters

The comprehensive renovation of a building that houses several Nissan, Kia, Hyundai and Citroën dealerships in Cocentaina (Valencia) has been carried out using a self-supporting deck roof system. The roof, with a surface area of ​​4,000 m², is designed on a spatial metal structure with supports spaced every 3 metres. For its rehabilitation, the INCO 100.3 Deck profile has been used, a high-edge profile with a 100 mm rib height, which provides significant advantages in terms of resistance and reduction of deformation.

The INCO 100.3 profile can cover spans of up to 8 metres, and depending on the type of project, the secondary structure can be dispensed with, which enables the direct support of the roof profile on the main structure, optimising labour and shortening execution times.

Start designing yout project

Request calculation report

Complete the form below to receive a detailed report justifying the most suitable enclosure profile. You will receive the information as soon as possible.

Building characteristics
Industrial roof application loads
(1) For sections of the roof profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Application loads for the industrial facade
(1) For sections of the façade profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that are presented in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Deck loads
(1) For sections of the roof profile with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Structure features
Composite slab characteristics
(1) For the sections of the composite slab with 2, 3, 4 or more supports, indicate the greatest distances between supports that appear in your project. Span length < 5,00 m.
Type of environment
Attached documentation
Additional comments
Contact information
Project data
Building characteristics
Characteristics of the facade
Roof typology

(1) Indicate the length of the span of the arch, which is the greatest horizontal distance between the supports of the curved roofing.

(2) Plan-view dimension representing the full length of the curved roof measured perpendicular to the arch span.

(3) Specify the obstructed area under the canopy, in square meters, as a proportion of the total area of the front or side (transverse or longitudinal) façade, in order to calculate the obstruction factor. If it is a closed construction or there is no obstruction area, indicate 0 m².

Environment characteristics
Type of environment
Attached documentation
Additional comments
Contact information
Project data